Hunter IBV-101G-FS 1" brass globe valve with flow control and Filter Sentry

A heavy-duty brass globe valve for dirty and reclaimed water. The factory-installed Filter Sentry scours the screen, and the flow control stem lets you trim the zone. Pressure loss at this size is in the chart above.

Performance

  • Flow 0.1 to 40 GPM at 20 to 220 psi
  • 24 VAC solenoid, 350 mA inrush and 190 mA holding at 60 Hz
  • Pressure loss 3.0 psi at 10 to 20 GPM, 20.0 psi at 40 GPM

Warranty: 5 years. Order at your trade pricing or pick up at ProSource in Kelowna, Westside, Burnaby, Vancouver, Langley or Calgary.

BrandHunter
Manufacturer part #IBV101GFS
UPC0611698152331
SeriesIBV brass globe valve with flow control
Valve size1"
Flow range0.1 to 40 GPM
Pressure range20 to 220 psi
Temperature rating150°F
Solenoid24 VAC
Solenoid inrush current350 mA at 60 Hz
Solenoid holding current190 mA at 60 Hz
MaterialBrass
Filter SentryFactory installed
Warranty5 years
  • Solid brass construction for maximum strength
  • Fabric-reinforced EPDM diaphragm and seat provide reliable operation in all water conditions
  • Filter Sentry ® Mechanism scours the filter screen in dirty and reclaimed water conditions
  • External/internal manual bleed allows for quick and easy activation at the valve
  • Reverse-porting solenoid design provides built-in pressure-surge and water-hammer protection
  • Heavy-duty brass construction provides high-pressure rating and reliability
  • Double-beaded diaphragm seal design ensures leak-free performance
  • Flow control maximizes efficiency and prolongs the life of the system
Pressure loss (psi) by flow
Flow (GPM)Pressure loss (psi)
0.12.0
0.52.0
12.0
52.5
103.0
153.0
203.0
309.0
4020.0