Rain Bird 2 in EFB-CP brass electric valve for reclaimed water
A red brass 2 in globe valve with a self-flushing screen that sheds debris in dirty or reclaimed water. EPDM diaphragm and chlorine-resistant parts, with a purple handle cover for non-potable lines.
Performance
- Flow range 5 to 200 GPM, with or without the PRS-D regulator
- Rated 15 to 200 psi and up to 150°F water
- 24 VAC solenoid: 0.41 A inrush, 0.14 A holding, ESP-LXD decoder compatible
Spec sheets are under Downloads. Order at your trade pricing or pick up at ProSource in Kelowna, Westside, Burnaby, Vancouver, Langley or Calgary.
| Brand | Rain Bird |
|---|---|
| Manufacturer part # | 200EFBCP |
| Series | EFB-CP, globe |
| Valve size | 2 in |
| Material | Red brass body and bonnet |
| Flow range | 5 to 200 GPM (1.14 to 45.4 m³/h) |
| Pressure range | 15 to 200 psi (1.04 to 13.8 bar) |
| Solenoid | 24 VAC, 50/60 Hz |
| Inrush current | 0.41 A (9.84 VA) at 60 Hz |
| Holding current | 0.14 A (3.43 VA) at 60 Hz |
| Coil resistance | 30 to 39 ohms |
| Water temperature | Up to 150°F (66°C) |
| Decoder compatibility | Compatible with ESP-LXD decoders |
| Dimensions | Height 7 in (17.8 cm), length 6 3/4 in (17.1 cm), width 5 3/4 in (14.6 cm) |
| PRS-D module adds | 2 in (5.1 cm) to valve height |
| Shipping weight | 7.2 lb |
- 2 in. (50/60) Brass Valve
- Normally closed, reverse flow design ensures valve will fail in the closed position if a tear or rip in the diaphragm occurs
- Prevents flooding, water waste and landscape damage
- Slow closing to prevent water hammer and subsequent system damage.
- One-piece solenoid design with captured plunger and spring for easy servicing
- Prevents loss of parts during field service
- Flow control handle adjusts water flow as needed
- Manual internal bleed operates the valve without allowing water into the valve box
| Flow (GPM) | Pressure loss (psi) |
|---|---|
| 20 | 0.5 |
| 30 | 0.6 |
| 40 | 0.8 |
| 50 | 1.1 |
| 60 | 1.8 |
| 80 | 2.4 |
| 100 | 3.8 |
| 120 | 5.9 |
| 140 | 7.8 |
| 160 | 10.0 |
| 180 | 12.5 |
| 200 | 15.8 |
Loss values are with flow control fully open; PRS-D module recommended for all flow ranges.