Hunter Industries
Flow-Clik System includes sensor and interface box, works with all standard 24 volt controllers (excludes sensor body - order separately)
$954.45
List price, excluding tax
Some prices are discounted with an account. Request an account, or sign in to see yours.
Availability by branch Checking stockCurrent stock
KelownaChecking…
WestsideChecking…
BurnabyChecking…
VancouverChecking…
LangleyChecking…
CalgaryChecking…
KelownaIn stock
WestsideOut of stock
BurnabyOut of stock
VancouverOut of stock
LangleyOut of stock
CalgaryOut of stock
Hunter Flow-Clik high-flow shutoff sensor kit with programming module
Adds high-flow shutoff to a standard 24 VAC controller. Set the highest flow you expect, and the module closes the system down if a pipe or head lets go. The FCT tee for your pipe size is ordered separately.
Performance
- Startup delay 0 to 300 seconds so system hydraulics settle
- Interrupt period 5 to 60 minutes, or manual reset
- Operating range per pipe size is in the chart above
Pairs well with
- 1" Schedule 40 FCT tee (HUN-FCT-100)
- 1.5" Schedule 80 FCT tee (HUN-FCT-158)
- 2" Schedule 40 FCT tee (HUN-FCT-200)
- 2" Schedule 80 FCT tee (HUN-FCT-208)
Warranty: 5 years. Order at your trade pricing or pick up at ProSource in Kelowna, Westside, Burnaby, Vancouver, Langley or Calgary.
| Brand | Hunter |
|---|---|
| Manufacturer part # | FLOWCLIK |
| UPC | 0611698126646 |
| Series | Flow-Clik sensor kit (sensor and programming module) |
| Input voltage | 24 VAC |
| Current draw | 0.025 A at 24 VAC |
| Switching current | 2 A maximum |
| Pressure range | 0 to 220 psi |
| Startup delay | 0 to 300 seconds, programmable |
| Interrupt period | 5 to 60 minutes, or reset manually |
| Sensor wiring | 2 conductor direct burial, 18 AWG or greater, up to 1,000 ft (304.8 m) from the programming module |
| Compatible controllers | All Hunter AC-powered controllers |
| Fitting required | FCT fitting for 1" to 4" pipe, sold separately |
| Warranty | 5 years |
- Automatically shuts down entire system if an overflow condition occurs, helping to protect against flood damage and erosion
- Single-button calibration to set highest expected flow rate
- User-adjustable timing and delay for sensor response
- Compatible with all Hunter AC-powered controllers for a variety of applications
- Multi-color LED indicates system status and if flow is within limits
| Pipe size | Minimum (GPM) | Suggested maximum (GPM) |
|---|---|---|
| 1" | 2 | 17 |
| 1 1/2" | 5 | 35 |
| 2" | 10 | 55 |
| 3" | 28 | 120 |
| 4" | 34 | 195 |