Store Locator Catalogue Quick Order Order Grid Sign in
Cart 0
Home / Catalogue / HUN-FLOW-CLIK
Flow-Clik System includes sensor and interface box, works with all standard 24 volt controllers (excludes sensor body - order separately)
Hunter Industries

Flow-Clik System includes sensor and interface box, works with all standard 24 volt controllers (excludes sensor body - order separately)

SKU HUN-FLOW-CLIK MPN FLOWCLIK Sold per 1
$954.45
List price, excluding tax
Sign in to order

Availability by branch Checking stockCurrent stock

KelownaChecking…
WestsideChecking…
BurnabyChecking…
VancouverChecking…
LangleyChecking…
CalgaryChecking…
KelownaIn stock
WestsideOut of stock
BurnabyOut of stock
VancouverOut of stock
LangleyOut of stock
CalgaryOut of stock

Hunter Flow-Clik high-flow shutoff sensor kit with programming module

Adds high-flow shutoff to a standard 24 VAC controller. Set the highest flow you expect, and the module closes the system down if a pipe or head lets go. The FCT tee for your pipe size is ordered separately.

Performance

  • Startup delay 0 to 300 seconds so system hydraulics settle
  • Interrupt period 5 to 60 minutes, or manual reset
  • Operating range per pipe size is in the chart above

Pairs well with

Warranty: 5 years. Order at your trade pricing or pick up at ProSource in Kelowna, Westside, Burnaby, Vancouver, Langley or Calgary.

BrandHunter
Manufacturer part #FLOWCLIK
UPC0611698126646
SeriesFlow-Clik sensor kit (sensor and programming module)
Input voltage24 VAC
Current draw0.025 A at 24 VAC
Switching current2 A maximum
Pressure range0 to 220 psi
Startup delay0 to 300 seconds, programmable
Interrupt period5 to 60 minutes, or reset manually
Sensor wiring2 conductor direct burial, 18 AWG or greater, up to 1,000 ft (304.8 m) from the programming module
Compatible controllersAll Hunter AC-powered controllers
Fitting requiredFCT fitting for 1" to 4" pipe, sold separately
Warranty5 years
  • Automatically shuts down entire system if an overflow condition occurs, helping to protect against flood damage and erosion
  • Single-button calibration to set highest expected flow rate
  • User-adjustable timing and delay for sensor response
  • Compatible with all Hunter AC-powered controllers for a variety of applications
  • Multi-color LED indicates system status and if flow is within limits
Operating range by pipe size
Pipe sizeMinimum (GPM)Suggested maximum (GPM)
1"217
1 1/2"535
2"1055
3"28120
4"34195