RAIN BIRD INTERNATIONAL INC.
Peb Series, 1 1/2" Electric Valve 24Vac
$348.38
List price, excluding tax
Some prices are discounted with an account. Request an account, or sign in to see yours.
Availability by branch Checking stockCurrent stock
KelownaChecking…
WestsideChecking…
BurnabyChecking…
VancouverChecking…
LangleyChecking…
CalgaryChecking…
KelownaIn stock
WestsideIn stock
BurnabyIn stock
VancouverIn stock
LangleyIn stock
CalgaryIn stock
Rain Bird 1 1/2 in PEB industrial plastic electric valve
A glass-filled nylon globe valve for commercial zones. Normally closed and slow closing, with a flow control handle and internal and external bleeds.
Performance
- Flows from 0.25 to 200 GPM (5 to 200 GPM with the PRS-D regulator fitted)
- Rated 20 to 200 psi and up to 150°F water
- 24 VAC solenoid: 0.41 A inrush, 0.14 A holding, ESP-LXD decoder compatible
- Install a Y filter upstream below 5 GPM or on Xerigation zones
Spec sheets are under Downloads. Order at your trade pricing or pick up at ProSource in Kelowna, Westside, Burnaby, Vancouver, Langley or Calgary.
| Brand | Rain Bird |
|---|---|
| Manufacturer part # | 150PEB |
| Series | PEB / PESB, globe |
| Valve size | 1 1/2 in |
| Material | Glass-filled nylon |
| Connection | NPT female × NPT female |
| Flow range | 0.25 to 200 GPM (0.06 to 45.4 m³/h) |
| Flow range with PRS-D | 5 to 200 GPM (1.14 to 45.4 m³/h) |
| Pressure range | 20 to 200 psi (1.38 to 13.8 bar) |
| Solenoid | 24 VAC, 50/60 Hz |
| Inrush current | 0.41 A (9.84 VA) at 60 Hz |
| Holding current | 0.14 A (3.43 VA) at 60 Hz |
| Coil resistance | 30 to 39 ohms |
| Water temperature | Up to 150°F (66°C) |
| Decoder compatibility | Compatible with ESP-LXD decoders |
| Low flow capability | 0.25 GPM (0.06 m³/h) |
| Dimensions | Height 8 in (20.3 cm), length 6 in (15.2 cm), width 6 in (15.2 cm) |
| PRS-D module adds | 2 in (5.1 cm) to valve height |
| Warranty | Five-year trade warranty |
| Shipping weight | 2.9 lb |
- Durable glass-filled nylon construction with fabric-reinforced rubber diaphragm for long life and reliable performance
- Globe configuration
- Normally closed, forward flow design
- Slow closing to prevent water hammer and subsequent system damage
- Low flow capability for a wide range of applications
- One-piece solenoid design with captured plunger and spring for easy servicing. Prevents loss of parts during field service
- Flow control handle adjusts water flows as needed
- Manual internal bleed manually operates the valve without allowing water into the valve box; allows pressure regulator to be adjusted without turning the valve on at the controller first
| Flow (GPM) | Pressure loss (psi) |
|---|---|
| 20 | 3.9 |
| 30 | 3.6 |
| 40 | 3.5 |
| 50 | 3.6 |
| 75 | 5.4 |
| 100 | 9.6 |
| 125 | 14.6 |
| 150 | 21.2 |
Loss values are with flow control fully open.